CX-MB-EVA2 User's Manual Hardware
34
4.13 Ethernet
The base board can be connected to a local area network with an Ethernet interface.
The COM Express module already provides MDI signals, so that only the transformer on
the base board required.
The transformer PULSE H 5004 not only supports 10BaseT and 100BaseTX but also
1Gbit.
Specification:
References: X33
Connector: AMP 2-406549
Pinout: Refer to IEEE Std. 802.3
[9, section three, page 225]
4.14 LPC Slot
An LPC slot is available for insertion of LPC expansion boards.
Specification:
References: X34
Connector: 36-pin header, 2.54mm
Pinout: Refer to Table 15
Pin
Signal
Pin
Signal
1
VCC5V
2
VCC5V
3
NC
4
VCC3V3
5
VCC3V3
6
NC
7
VCC3V3_SBY
8
GND
9
GND
10
LPC_RST#
11
GND
12
LPC_LAD0
13
LPC_LAD1
14
LPC_LAD2
15
LPC_LAD3
16
LPC_FRAME#
17
GND
18
LPC_DRQ0
19
GND
20
LPC_CLK
21
GND
22
LPC_PWRDWN
23
GND
24
PME#
25
GND
26
LPC_SMI#
27
GND
28
SERIRQ
29
GND
30
PCI_CLKRUN#
31
GND
32
LPC_DRQ1#
33
GND
34
CPU_RST#
35
GND
36
GND
Table 20 Pinout LPC-Slot